Nanotube in VASP

To make a suitable POSCAR file from the graphene sheet,

$ c2x -y=7,0 -v --vasp graphene.cell POSCAR

The KPOINTS file used was

Automatic mesh
0              ! automatic generation
M
1 1 2          ! grid
0. 0. 0.       ! shift

and the INCAR used was

encut = 400
lvtot = .TRUE.
lvhar = .TRUE.
ialgo = 48

A suitable POTCAR is also required.

(For the analysis below, a minimum c2x version of 2.34d is required.)

The potential far from the tube (i.e. at (0,0,0)) and at the centre of the tube (i.e. at (0.5,0.5,0.5)) can then be recovered as:

$ c2x -z='(0,0,0)' LOCPOT 
Potential_eV at (0.000000,0.000000,0.000000): 3.790117e+00
$ c2x -z='(0.5,0.5,0.5)' LOCPOT 
Potential_eV at (0.500000,0.500000,0.500000): 3.222546e+00

So the difference is 0.568V

Alternatively, the electrostatic potential can be calculated from the density with:

$ c2x -E -z='(0,0,0)' CHGCAR
Potential_Volts at (0.000000,0.000000,0.000000): -3.883333e+00
$ c2x -E -z='(0.5,0.5,0.5)' CHGCAR
Potential_Volts at (0.500000,0.500000,0.500000): -3.311769e+00

And the difference is now 0.572V.

In common with most DFT codes, Vasp's definition of the local potential differs in sign from the electrostatic potential.

If one wishes Vasp to include the exchange-correlation potential in the LOCPOT file, then the parameter lvhar should be false, which is its default value.