Projected Densities of States and Nanotubes

Using c2x one can project densities of states onto hollow cylinders. This can be useful for studying the inside and outside surfaces of nanotubes. This page describes all the steps of a calculation with Castep.

Graphene to Nanotube

The starting point is a graphene sheet, here described by a .cell file.

%block LATTICE_CART
  2.4577810   0.0000000   0.0
  1.2288905   2.1285008   0.0
  0.0000000   0.0000000  24.0
%endblock LATTICE_CART

%block POSITIONS_FRAC
  C  0.3333333333  0.3333333333  0.500000000
  C  0.6666666667  0.6666666667  0.500000000
%endblock POSITIONS_FRAC

This can then be converted into a nanotube.

$ c2x -y=8,0 --cell graphene.cell tube.cell

In order to perform the DOS calculations, some kpoint grids are defined by appending to the tube.cell file the two lines

kpoint_mp_grid 1 1 6
spectral_kpoint_mp_grid 1 1 16

and it is necessary to provide a tube.param file, suitable contents for which would be

task            spectral
spectral_task   DOS
write_orbitals  true

The above should run in about fifteen core-minutes.

Nanotube DOS and LDOS

The nanotube is centred on a=b=0.5, so to find its radius one looks for a carbon atom one of whose a or b fractional co-ordinates is 0.5,

  C  0.724967318  0.500000000  0.333333333

and concludes that the fractional radius must be 0.224967318. As the lattice is 14A in this direction, the radius is 3.15A.

So to calculate the full DoS, the LDoS from the centre of the tube to 1.5A inside, and the LDoS from the centre of the tube to 1.5A outside, the commands would be

  $ c2x --dos_gnu:G tube.orbitals DOS.gnu
  $ c2x -v --dos_gnu:G --ldos=M:r1.65-3.15 tube.orbitals inside.gnu
  $ c2x -v --dos_gnu:G --ldos=M:r3.15-4.65 tube.orbitals outside.gnu

The first command will run almost instantaneously. The LDOS projections are significantly slower, hence the use of -v to show a progress indicator. However, for this small system they are not that slow, a little over ten seconds each.

The three plots look very similar.

Nanotube DoS

Nanotube DoS inside

Nanotube DoS inside surface

Nanotube DoS outside

Nanotube DOS outside surface

The integrated density in the outside plot is greater than that for the inside plot, but its volume is also greater.

To demonstrate that these plots might be doing what is claimed, a plot projected on a cylinder from 5A to 7A.

$ c2x -v --dos_gnu:G --ldos=M:r5-7 tube.orbitals vacuum.gnu

Nanotube PDoS in vacuum region

Now something very different is seen, with almost no density below the Fermi level. States far outside the tube are all unoccupied excited states.

One can also try an inner core at a similar distance (M:r0-1.3), and the plot is similar, but with a much smaller weight.

Graphene DOS and LDOS

One can perform similar calculations on the graphene sheet. The same .param file can be used, and suitable kpoint meshes to add to the .cell file are

kpoint_mp_grid 8 8 1
spectral_kpoint_mp_grid 16 16 1

In order to speed up the calculation, the extent of the c axis was reduced from 24A to 14A. And to ensure that a similar fraction of unoccupied bands was calculated, spectral_nbands was set to 8 in the param file.

The result will not be identical, as the k-point sampling is different, and the nanotube calculation had 121 bands for 32 atoms (3.78 bands per atom), whereas the graphene calculation had eight bands for two atoms (4.0 bands per atom). Anyway, a graphene sheet is not identical to a nanotube.

Graphene DoS

One can look at the different projected DoSes for the plane of the C atoms, and above that plane. One would expect the plane to be dominated by the σ bonds, and the area immediately above by the π bonds.

$ c2x --dos_gnu:G --ldos=6.8-7.2C graphene.orbitals graphene_core.gnu
$ c2x --dos_gnu:G --ldos=7.5-8.2C graphene.orbitals graphene_surface.gnu

LDoS, graphene core

PDoS within 0.2A of graphene

PDOS, graphene surface

LDoS from 0.5A to 1.2A above graphene

The near-plane LDoS shows a large gap-like region of around 10eV, and significant density down to -20eV. In contrast the out-of-plane plot shows a sharp rise at -10eV, and a much smaller gap of only a couple of eV. This is consistent with π and π* states being close to the Fermi level and having weight some distance from the plane and little weight close to it, whereas the σ and σ* states may be further away from the Fermi level, both below and above, and lie close to the plane of the atoms.